rodlift.flow.friction¶
rodlift.flow.friction ¶
Single-phase friction factors.
References
.. [Colebrook1939] Colebrook, C.F. (1939). "Turbulent flow in pipes, with particular reference to the transition region between the smooth and rough pipe laws." J. Inst. Civil Eng., 11(4), 133-156. .. [DunsRos1963] Duns, H. Jr. and Ros, N.C.J. (1963). "Vertical flow of gas and liquid mixtures in wells." Proc. 6th World Petroleum Congress, Frankfurt, 451-465. .. [DrewKooMcAdams1932] Drew, T.B., Koo, E.C. and McAdams, W.H. (1932). "The friction factor for clean round pipes." Trans. AIChE, 28, 56-72.
moody_friction_factor ¶
moody_friction_factor(
reynolds: float,
relative_roughness: float = 0.0,
*,
laminar_limit: float = 2100.0,
) -> float
Moody (Darcy-Weisbach) friction factor.
Re <= laminar_limit:f = 64/Re.ε/D < 0.05: Colebrook's equation [Colebrook1939]_, solved to machine precision.ε/D >= 0.05: Duns & Ros' extension for very rough walls [DunsRos1963]_,f = 4[1/(4 log₁₀(0.27 ε/D))² + 0.067 (ε/D)^1.73].
Parameters:
| Name | Type | Description | Default |
|---|---|---|---|
reynolds
|
float
|
Reynolds number (> 0). |
required |
relative_roughness
|
float
|
Relative roughness ε/D (≥ 0). |
0.0
|
laminar_limit
|
float
|
Reynolds number below which the flow is treated as laminar. |
2100.0
|
fanning_friction_factor ¶
fanning_friction_factor(
reynolds: float,
relative_roughness: float = 0.0,
*,
laminar_limit: float = 2300.0,
) -> float
Fanning friction factor, one quarter of :func:moody_friction_factor.
smooth_pipe_fanning ¶
smooth_pipe_fanning(
reynolds: float, *, laminar_limit: float = 2300.0
) -> float
Fanning friction factor for smooth pipe, Drew, Koo & McAdams [DrewKooMcAdams1932]_.
f = 0.0014 + 0.125 Re^-0.32 in turbulent flow, 16/Re in laminar flow.